In automotive and industrial electronics, an HSD (High-Speed Data) cable assembly is a harness built around the automotive 100 Ω differential HSD interconnect system, used for digital links between infotainment head units, displays, camera modules, instrument clusters, and USB ports. Despite sharing the "high-speed data" abbreviation, an automotive HSD cable assembly uses a dedicated vehicle connector and cable interface—not a consumer HDMI, DisplayPort, USB-C, or Thunderbolt audio/video cord.
When identifying or selecting an HSD assembly, the primary structural distinction is between standard 4-pin HSD and 4+2 (HSD+2) designs: a standard 4-pin assembly uses a four-contact data interface paired with a star-quad cable, while a 4+2 assembly retains that four-contact data section and adds two MQS contacts for power supply.
What Is an HSD Cable and How Does the 4-Pin Structure Work?
The standard four-contact HSD design covered in this guide pairs a four-position connector cavity with a star-quad cable. Within the Rosenberger HSD interconnect system, other specialized variants also exist—such as HSDt, which uses a single twisted differential pair—depending on the vehicle link design.
How Star-Quad Conductors Form Two 100 Ω Differential Pairs
The term star-quad describes the arrangement of the four insulated conductors twisted together inside the cable core, rather than the shape of the connector housing. As shown in the HSD Technical References, the four conductors sit symmetrically around a central axis so that diagonally opposite conductors form a balanced 100 Ω differential pair, giving a standard star-quad cable two orthogonally arranged differential pairs.

Here, 100 Ω refers to the high-frequency differential characteristic impedance of each conductor pair along the transmission line—not a 100 Ω DC resistance target that you would measure from one end of a bare wire to the other with a handheld multimeter. Actual shielding construction, noise performance, and operating frequency are not identical across every cable assembly on the market; they depend on the specific cable type, shield termination, and harness routing.
Why 4 Pins Do Not Mean 4 Independent Data Channels
Looking at four contacts inside an HSD connector can make it tempting to assume the cable carries four separate data channels. As explained in Texas Instruments' LVDS Application Note (SCDA012A), a differential receiver recovers a signal from the voltage difference between two paired conductors. Because two conductors work together to carry a single differential signal (rather than one wire exclusively transmitting and the other receiving, or each pin acting as an independent single-ended channel), a four-contact HSD interface provides at most two differential pairs.
Even with two differential pairs available in a star-quad core, a vehicle link does not automatically use both pairs as two independent high-speed data streams. Depending on the module design, one pair may transmit high-speed video or serial data while the remaining conductors are assigned to control signaling or power delivery.
HSD Interconnects vs. LVDS and Application Systems
Buyers searching for a display or camera harness often ask for an "HSD LVDS cable." Separating the physical connector system from the electrical signaling method clarifies what that name actually covers:
- HSD is the 100 Ω physical interconnect system: It defines the connector interface, mechanical latching and coding geometry, and—in the standard four-contact configuration covered here—the star-quad cable structure.
- LVDS (Low-Voltage Differential Signaling) is an electrical signaling method: Per the TI LVDS Application Note, LVDS specifies driver and receiver electrical characteristics and does not define the communication protocol, interconnect, or connector details.
In vehicle architectures, HSD cable assemblies are used across display and camera links, automotive USB connections, and other digital interfaces. However, knowing that both devices use HSD connectors—or that both carry LVDS signals—does not automatically make any two HSD harnesses interchangeable in pinout or system protocol. Moreover, as shown in the HSD Technical Data and Interface Pinnings overview, usable operating frequency depends on the specific cable type used in the assembly, so MHz or GHz frequency ratings cannot be treated as a single universal Gbps data rate for all HSD cables.
4-Pin vs. 4+2 HSD Cables: Contacts and Power Supply
Inspecting the mating face of an HSD port or cable plug reveals whether the interface contains only the four-contact data section or includes additional power contacts.
Structural Differences: Standard 4-Pin, 4+2 (HSD+2), and Dual HSD
Based on the contact partitioning in the HSD Technical References, these interfaces are organized as follows:

Standard 4-Pin HSD: Contains the four-contact HSD data section arranged for the star-quad cable core.

4+2 (HSD+2): Retains the four-contact HSD data section and adds two MQS power contacts located outside the four-contact data section (with HSD+4 and HSD+8 variants adding four or eight MQS power contacts outside the data cavity in the same way).

Dual HSD: Places two four-contact HSD data cavities side by side in one housing (eight HSD contacts total), forming a two-cavity data interface rather than a 4+2 power-plus-data connector.
Adding the +2 MQS contacts does not by itself increase data bandwidth, and you cannot judge one cable assembly to be faster simply because it is a 4+2 variant. The two MQS contacts are for power supply, whereas high-speed signal performance is determined by the four-contact HSD data section, the cable specification, and the connected transceivers.
4-pin and 4+2 cable examples

4-pin HSD cable
Z code · Straight ends · 0.5 m
Four contacts within each data cavity.
View EB-014-0336-C (50792)
4+2 HSD cable
Z code · Straight ends · 1 m
How Power Is Supplied in 4-Pin vs. 4+2 Systems
Both 4-pin and 4+2 HSD assemblies can appear in powered links, depending on how the connected equipment is engineered:
Can You Substitute a 4-Pin Cable for a 4+2 Assembly?
Whether a 4-pin and a 4+2 assembly can substitute for one another depends on both the mechanical interface and the circuit power path:
- When the equipment relies on the
+2contacts for power: If a display, camera, or hub is designed to receive or supply power through the two MQS contacts outside the data cavity, a standard 4-pin cable lacks that power path and cannot serve as a complete replacement. - When the system is built for a 4-pin power scheme: If the original link supplies power over the four-contact interface, adding the two power contacts does not by itself improve data performance (though individual cable assemblies may still differ in other specifications), and a 4+2 harness will not match the circuit unless the device ports and wiring are specifically designed for it.
Because not every port with +2 contacts uses the exact same functional wiring, mechanical mating, signaling compatibility, voltage, polarity, required current, and return path must all be confirmed against the equipment and harness documentation before attempting any substitution.
HSD vs. FAKRA, Mini FAKRA, and H-MTD Interfaces
Automotive control units frequently group several high-frequency ports on the same rear panel. You can distinguish 100 Ω HSD interfaces from adjacent coaxial and differential connector families by their conductor structure and port layout.
HSD (100 Ω Differential) vs. FAKRA and Mini FAKRA (50 Ω Coaxial)

Four coaxial ports

One HSD data cavity
Standard FAKRA connectors and Mini FAKRA systems such as Rosenberger HFM (High-Speed FAKRA-Mini) are 50 Ω coaxial interconnects, where each port terminates a single center conductor surrounded by a concentric shield. HFM is available in single, double, and quad port housings (note that HFM is one specific Mini FAKRA system rather than a universal specification for all manufacturers' mini coaxial products).
By contrast, the standard four-contact HSD configuration is a 100 Ω balanced differential interface containing four contacts inside a single cavity. A four-port (quad) FAKRA or Mini FAKRA connector groups four separate 50 Ω coaxial ports into one outer shell—it is mechanically and electrically distinct from a single 4-pin HSD port. For a detailed comparison of coaxial options, see our Mini FAKRA vs. FAKRA selection guide.
HSD vs. H-MTD (100 Ω Differential Family)
The H-MTD connector system is an independent 100 Ω differential connector family offered in single- and multi-port housings for STP or UTP cables. H-MTD is used in Automotive Ethernet links as well as other high-speed vehicle applications, and it uses a different cavity geometry and mating interface from HSD. If your project targets Ethernet harnesses, see our Automotive Ethernet and H-MTD cable assembly guide.
Across all of these connector families, keep in mind that a passive hybrid cable assembly is not a protocol converter: changing passive connector ends only adapts physical terminations and cannot by itself establish protocol or electrical compatibility between two devices.
How to Choose and Verify an HSD Cable Assembly
Because the HSD connector standard defines the physical interface while the equipment designer defines the circuit assignment, follow these five verification steps across both ends of the harness before ordering.
1. Identify the Connector Interface at Both Ends (End A and End B)
Inspect both equipment ports or existing cable ends to confirm whether each side is a standard 4-pin HSD, a 4+2 (HSD+2), a Dual HSD, or a transition to another interface. Record any part numbers or series markings stamped on the connector shells.
2. Check Mechanical Coding Ribs and End-to-End Compatibility
HSD housings use mechanical keying ribs along the barrel paired with color codes to prevent cross-plugging adjacent ports. However, sharing the same housing color or contact count does not guarantee electrical compatibility, nor does it alone prove two connectors will mechanically mate. Where a neutral or Z-coded connector is used, check the manufacturer's coding specification to confirm which keyed housings it can mate with. Beyond physical mating, confirm that the two connected devices have compatible signaling interfaces and that the cable's end-to-end wiring map matches both ports—do not assume every harness is wired 1-to-1 (pin 1 to pin 1).
3. Separate Contact Gender from Housing Shape and Cable Exit
In HSD assemblies, male (pin) and female (socket) describe the physical contact gender inside the cavity—they do not refer to the outer locking shell alone, and they never indicate signal transmit/receive direction or which side supplies power. Check contact gender at both End A and End B, and verify whether each end requires a straight or right-angle cable exit oriented to clear surrounding brackets per the assembly drawing.

Right-angle HSD cable
4-pin · Z code · 1 m
Both ends have a 90° cable exit.
View EB-101-0281 (4799)4. Confirm Pin Assignment, Viewing Plane, and Power Polarity
Standard contact numbers on a connector drawing only label physical positions—do not infer a universal 1–6 pinout map simply from the "4+2" name, and instead check the specific interface and harness drawings. When reading a pinout diagram, always verify the drawing viewing plane—whether the view shows the mating face or the cable-termination (rear) side—because flipping the view reverses the contact positions. Especially on 4+2 harnesses with external power leads, never guess voltage or polarity from red and black wire insulation alone; confirm the exact pin-to-pin signal map, voltage, polarity, required current, and return path against the system schematic.


5. Account for Cable Length, Routing, and Continuity Check Limits
Usable cable length and signal quality depend jointly on the cable specification, overall length, shield termination, routing bend radius, environmental rating, and transceiver requirements; there is no single universal length limit or Gbps figure for all HSD assemblies. If you perform a handheld multimeter continuity check, do so only on an unpowered cable assembly disconnected from both devices to verify a known pin-to-pin wiring map or check for open/short faults. Because 100 Ω refers to high-frequency differential characteristic impedance rather than DC wire resistance, a basic continuity test cannot verify 100 Ω impedance performance, pair skew, or high-speed system compatibility.
If you do not have the complete harness drawing on hand, gather clear mating-face photos of both ports, the housing part numbers and coding letters, contact genders, required exit directions, and both device model numbers so your equipment manufacturer or harness supplier can confirm the exact interface and pin assignment before you order. Keep in mind that while photos help identify the physical connector style, they cannot by themselves prove internal wiring order, voltage levels, or device compatibility.
Pre-Order Specification Recording Worksheet
Copy the fields below into your project notes or inquiry sheet to log the required specifications for both ends of your cable assembly:
- End A (Port / Cable Side 1)
- Interface Type:
____________________ - Part Number & Coding Key:
____________________ - Contact Gender (Pin / Socket):
____________________ - Cable Exit (Straight / Right-Angle):
____________________
- Interface Type:
- End B (Port / Cable Side 2)
- Interface Type:
____________________ - Part Number & Coding Key:
____________________ - Contact Gender (Pin / Socket):
____________________ - Cable Exit (Straight / Right-Angle):
____________________
- Interface Type:
- Link Wiring, Power & Cable Spec
- End-to-End Pin Map & Viewing Plane:
____________________ - Power Path, Voltage, Polarity & Current:
____________________ - Cable Length, Cable Type & Environment:
____________________
- End-to-End Pin Map & Viewing Plane:
Once you have recorded your endpoint specifications and confirmed the wiring requirements, you can browse available HSD cable assemblies to select a matching configuration.